Certifications and safety

The tests, the laboratories, the standards

Fire classification in Europe and the United States, accredited thermal tests, regulatory framework and safety data sheet of the core. Everything an engineer or a purchasing office wants to see before saying yes.

B-s1,d0fire classification EN 13501-1:2019 · Istituto Giordano
Class AASTM E84 (USA): flame-spread index 5, smoke-developed index 5
ACCREDIAaccredited laboratories: Istituto Giordano (fire) and Certimac ENEA-CNR (thermal)
Not regulatedtransport: not classified as dangerous goods (DOT, TDG)
Fire · Europe

Reaction to fire B-s1,d0

Very limited contribution to fire (B), absent or negligible smoke production (s1), no burning droplets or particles (d0). Classification to EN 13501-1:2019 based on two tests carried out by Istituto Giordano. The panels are not flammable and do not spread fire: the inorganic composition of the core makes them fire-resistant.

Single-flame test · EN ISO 11925-2:2020

Six specimens (three longitudinal, three transverse), flame applied both on the surface and on the edge. Result on all: the flame does not reach 150 mm and does not ignite the filter paper.

AttackSpecimensFs 150 mmCf paper
On the surface1-6 (L and T)No on allNo on all
On the edge1-6 (L and T)No on allNo on all

Single burning item test · EN 13823:2022

ParameterS1S2S3Mean
FIGRA 0.2 MJ [W/s]0001
FIGRA 0.4 MJ [W/s]0041
LFS at edgeNoNoNo
THR 600 s [MJ]0.50.30.20.3
SMOGRA [m²/s²]0000
TSP 600 s [m²]7736
Droplets ≤ 10 s / > 10 sNo / NoNo / NoNo / No

The laboratory charts (HRR, THR, FIGRA, SPR, TSP, SMOGRA) are in the full test report, available on request.

Fire · United States

ASTM E84 · Class A

In the American Steiner-tunnel test the panel achieves flame-spread index 5 and smoke-developed index 5 (maximum allowed 450 for both): the highest class. Ignition time 0.10 minutes, maximum spread distance 41.15 cm, time to maximum spread 1.68 minutes. Estimated NFPA rating of the core: health 1, flammability 0, reactivity 0.

Thermal tests · Certimac (ENEA-CNR)

Conductivity, specific heat, reflectance

QuantityValueMethod
Thermal conductivity at 0 °C (solid phase)0.346 - 0.407 W/mKASTM E1530, EN 12664
Thermal conductivity at 50 °C (liquid phase)0.456 - 0.489 W/mKguarded heat-flow meter
Specific heat between −25 and −15 °C1.039 - 1.161 J/(g·°C)MDSC, ISO 11357-1
Specific heat between 40 and 70 °C1.993 - 2.062 J/(g·°C)MDSC, ISO 11357-1
Solar reflectance index SRI81 (glossy side) · 97 (matt side)ASTM E1980
Mean solar reflectance0.83 · 0.82ASTM E903, G173
Thermal emissivity0.05 (glossy) · 0.58 (matt)ASTM C1371
Regulatory framework

Standards met

  • Directive 2001/95/EC on general product safety and the Italian Consumer Code (Legislative Decree 206/2005)
  • IEC 61882:2016 HAZOP risk analysis · IEC 61511-1:2016 functional safety
  • EN 13172:2012 thermal insulation products, evaluation of conformity
  • EN 13786:2009 time shift and periodic thermal transmittance
  • UNI 10351:2015 and UNI 10355:2013 hygrothermal properties of materials, masonry and floors
  • EN ISO 6946 thermal resistance and transmittance of building components
  • EN 13501-1:2019 fire classification · ASTM E84 for the US market
CE marking

The ETA procedure

There is no harmonised European standard yet for phase-change panels: the obligation of CE marking and declaration of performance only starts with the publication of the standard in the Official Journal and the end of the coexistence period. Meanwhile TI-SKIN follows the ETA procedure (European Technical Assessment), already activated, which allows sale pending the final mark. One-off products, products made to the client's specification or for a specific work remain outside the obligation anyway.

The safety data sheet

The core, in plain words

The core is a mixture of hydrated salts (sodium sulphate 45-60%, sodium tetraborate under 5%, hydrated magnesium aluminosilicate 10-25%, water 35-60%), sealed in a heat-sealed, water-tight multilayer film. In this configuration the product is a very low hazard for its intended uses. The full sheet (16-section MSDS, 2026 edition) is document 04 of the series.

Hazards and first aid

No risk in normal use. Only if the film is torn with the core in liquid phase: possible mild irritation of eyes and skin. Rinse with water for 15 minutes; if swallowed do not induce vomiting and drink water; see a doctor if discomfort persists. Inhalation is practically impossible: the material is a solid or a pudding-like liquid.

Fire and stability

Non-flammable material; use the extinguishing agent appropriate to the surrounding fire. Stable at room temperature in closed packaging; the change of state occurs inside the package between about 24 and 30 °C. No incompatibility with other materials, no hazardous polymerisation.

Handling and storage

Gloves recommended for a better grip on the film; wash hands after handling. Avoid high-traffic areas where the film might be punctured. Store in the original packaging, out of direct sunlight.

Toxicology

The components are not listed as carcinogens by IARC, NTP or OSHA. Low acute toxicity (oral LD50 in rats 918-1,668 mg/kg; dermal in rabbits above 5,000 mg/kg). Once packaged no respirable silica is present.

Environment

Does not deplete oxygen in water, low potential to affect aquatic organisms and treatment sludge, no bioaccumulation. The mineral fraction is insoluble in water and not biodegradable.

Transport and disposal

Not classified as dangerous goods for transport (DOT 49 CFR 172.101, TDG). At end of life the panel is removed and reused; for disposal follow local rules: separate collection of packaging, no landfill where recycling exists, out of the reach of children.

Research

Studies and references

Politecnico di Torino (equivalent thermal properties with dynamic heat-flow meter; on-site roof monitoring), University of Reggio Calabria (olive-oil storage with phase-change materials; NZEB containers), University of Ferrara with Cádiz, USTC and Nottingham (ventilated roofs), University of Calabria (SUSTANZEB project), Politecnico di Milano (photovoltaics), IUAV Venice and ENEA Casaccia (characterisation of static and dynamic insulation), ENEA Palermo (latent thermal management, active walls), CNR Pisa (DEMO LIFE project). The full list is in the Compliance sheet and on the Projects page.

Documents to download

The full series is on the Documents page. Price list and terms of supply on request.

Request an assessment

Every building and every process has its own configuration. Tell us about yours: we reply with a first technical assessment, no strings attached.